Impact of date stamping on patient safety measurement in patients undergoing CABG: experience with the AHRQ Patient Safety Indicators

BMC Health Serv Res. 2008 Aug 13:8:176. doi: 10.1186/1472-6963-8-176.

Abstract

Background: The Agency for Healthcare Research and Quality (AHRQ) Patient Safety Indicators (PSIs) provide information on hospital risk-adjusted rates for potentially preventable adverse events. Although designed to work with routine administrative data, it is unknown whether the PSIs can accurately distinguish between complications and pre-existing conditions. The objective of this study is to examine whether the AHRQ PSIs accurately measure hospital complication rates, using the data with present-on-admission (POA) codes to distinguish between complications and pre-existing conditions

Methods: Retrospective cohort study of patients undergoing isolated CABG surgery in California conducted using the 1998-2000 California State Inpatient Database. We calculated the positive predictive value of selected AHRQ PSIs using information from the POA as the gold standard, and the intra-class correlation coefficient to assess the level of agreement between the hospital risk-adjusted PSI rates with and without the information contained in the POA modifier.

Results: The false positive error rate, defined as one minus the positive predictive value, was greater than or equal to 20% for four of the eight PSIs examined: decubitus ulcer, failure-to-rescue, postoperative physiologic and metabolic derangement, and postoperative pulmonary embolism or deep venous thrombosis. Pairwise comparison of the hospital risk-adjusted PSI rates, with and without POA information, demonstrated almost perfect agreement for five of the eight PSI's. For decubitus ulcer, failure-to-rescue, and postoperative pulmonary embolism or DVT, the intraclass-correlation coefficient ranged between 0.63 to 0.79.

Conclusion: For some of the AHRQ Patient Safety Indicators, there are significant differences in the risk-adjusted rates of adverse events depending on whether the POA indicator is used to distinguish between pre-existing conditions and complications. The use of the POA indicator will increase the accuracy of the AHRQ PSIs as measures of adverse outcomes.

Publication types

  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • California
  • Cohort Studies
  • Coronary Artery Bypass / standards*
  • Humans
  • Medical Errors / statistics & numerical data*
  • Postoperative Complications / epidemiology*
  • Quality Indicators, Health Care*
  • Retrospective Studies
  • Risk Adjustment
  • Safety Management / standards*
  • Treatment Outcome
  • United States
  • United States Agency for Healthcare Research and Quality